AAC AAAC ACSR TACSR ACAR Overhead Bare Conductor IEC ASTM BS DIN Standards
1. AAC/AAAC Conductor
Application:
Mainly for Overhead power transmission and primary and secondary distribution
Applicable standards:
AAC: ASTM B 231, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089, GB/T 1179, JIS3109,CSA C49,BS215
AAAC: ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089, GB/T 1179,BS3242
Production Scope:
Max. Cross-Section 5000MCM/2500mm2,Max. Stranded number 127Nos.
Construction:
For AAC: Type 1350-H19 aluminium wires, concentrically stranded;
For AAAC: Type 6201-T81 aluminium wires, concentrically stranded.
2. ACSR/AACSR /TACSR Conductor
Application: Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR/AACSR/TACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without reducing ampacity.
Applicable Standards:
ASTM B-232, BS EN-50182, CSA C 61089, AS/NZS 3607, DIN 48204, IEC 61089, GB/T 1179, JIS 3110.CSA C49,ASTM B711
Production Scope:
Max. cross-section 3500MCM/1750mm2, Max. Stranded Number 127Nos.
Construction:
For ACSR: Type Aluminium 1350-H19 wires,concentrically stranded around galvanize coated steel core wire
For AACSR: Type Aluminium alloy 6201-T81 wires, concentrically stranded around galvanize coated steel core wire
For TACSR: Thermal resistant aluminium alloy wires, concentrically stranded around galvanize coated steel core wire
3. ACAR Conductor
Application: Aluminum Conductor Alloy Reinforced (ACAR) cable is an excellent conductor choice where current carrying capacity, higher strength and a lower conductor weight are critical to the line design.
Applicable standards:
ASTM B-524, BS EN-50182, CSA C 61089,IEC 61089, GB/T 1179
Production Scope:
Max. cross-section 3500MCM/1750mm2, Max. stranded number 127Nos.
Construction:
Aluminum Conductor Alloy Reinforced (ACAR) cable has aluminum 1350 H-19 wires stranded around a 6201-T81 aluminum alloy core concentrically.
4. GSW/ACS/CCS Conductor
Application:
Galvanized Steel wire (GSW) is used for staying the poles or as the core of ACSR
Aluminium Clad Steel (ACS) used as lighting conductor ground wire;
Copper Clad Steel (CCS) used as ground wire
Applicable Standards:
GSW: ASTM A475. BS183. CAN/CSA-G12
ACS: ASTM B416. YB/T 124-1997.
CCS: ASTM B288
Production Scope:
Wire dia. from 1.20mm to 5.60mm, Max. Stranded Number: 37 No.s.
Construction:
Galvanized Steel/Aluminum Clad Steel/Copper Clad Steel Wire, concentrically Stranded.